The overload protector (labeled "B" below) is connected by two wires. One wire connects
to the compressor relay (labeled "A") with a slip-on
connector. Pull the connector firmly off of the relay terminal
(do not pull on the wire). You may need to use a pair of needle-nose
pliers to remove the connector. Inspect the connector for
corrosion. If the connector is corroded it should be cleaned
or replaced.
The overload protector is held in place with
a round spring clip. Using a screwdriver, pry open the spring
clip and remove the overload protector.
Reattach the wires to the new
overload protector. Open the spring clamp and place the overload
protector in position. Release the spring clamp to hold the
protector in place. Replace the terminal cover box and plug
in the refrigerator.